VSP-1500 Syringe Pump
3,659.04 د.إ.
Guaranteed safe payment
Request it within the next [totalHours] hour %M minute to get it between and
Features
- Open System: Accepts all standard syringes of sizes 5 ml, 10 ml, 20 ml/30 ml, 50 ml/60 ml.
- Large Color LED Screen
- KVO/Bolus Function
- Vertical and horizontal installation.
- Anti-bolus system to significantly reduce sudden release after occlusion.
- Three levels of occlusion pressure alarm.
- Three operating modes: rate mode, time mode, dose mode
- Automatically identify syringe specifications.
- Audible and visual alarm: Syringe holder not Fixative, syringe plunger release, Error in syringe flange insertion, syringe not calibrated, occlusion, empty syringe, abnormal rate, empty battery, no battery, key press during infusion, key press during stop, infusion complete, syringe near empty, no action, low battery level, out of flow range
- Stackable: Users can freely stack one syringe pump on top of another to provide multiple solutions
- Power loss memory.
- Visual and audible alarm system and precise injection rate make the process safer and more reliable.
- Change the flow rate without stopping during infusion.
- Continuous operation for 8-10 hours using an internal lithium battery.
- Precise and sensitive pressure sensor accurately detects occlusion pressure.
- Excellent injection process. Accuracy will be ensured even with small volume injections.
Technical specifications
- Parameters
- Specification
- Applicable injections: 5 ml, 10 ml, 20 ml, 30 ml, 50 ml, 60 ml of any standard size
- Accuracy: +/- 2% with correct calibration
- Rate mode
- 50 ml (60 ml): 0.1 ml/hour - 2000.0 ml/hour (step 0.1 ml/hour or 1 ml/hour)
- 30 ml: 0.1 ml/hour - 1200.0 ml/hour (step 0.1 ml/hour or 1 ml/hour)
- 20 ml: 0.1 ml/hour - 800.0 ml/hour (step 0.1 ml/hour or 1 ml/hour)
- 10 ml: 0.1 ml/hour - 400.0 ml/hour (step 0.1 ml/hour or 1 ml/hour)
- 5 ml: 0.1 ~ 200 ml/hour (step 0.1 ml/hour or 1 ml/hour)
- Time mode
- SOL. VOL: 0.1-9999.9 ml (step 0.1 ml)
- TIME: 00:01-99:59 minutes (step 1 minute)
- Dose mode
- Volume: 0.1-999.9 ml (step 0.1 ml)
- Drug mass: 0.1-999.9 mg (step 0.1 mg)
- Dose: 0.001-9999 mcg/kg/min (step 0.001 mcg/kg/min)
- Weight: 0.1-300 kg (0.1 kg minimum step)
- Dose unit: ng/kg/min, mcg/kg/min, mg/kg/min, g/kg/min, mcg/hour, mg/hour, g/hour, mcg/min, mg/min, g/min, mcg/hour, mg/hour, g/hour, unit/min, unit/hour, IU/hour, unit/kg/hour, ml/hour
- Total volume range
- 0.1-9999 ml (step 0.1 ml)
- Flush rate
- 50 ml (60 ml): 1500.0 ml/hour, 30 ml: 1200.0 ml/hour, 20 ml: 800.0 ml/hour, 10 ml: 400.0 ml/hour, 5 ml: 200 ml/hour
- KVO rate
- 3 ml/hour when the delivery rate is ≥3 ml/hour, otherwise KVO is the actual delivery rate
- Dynamic Pressure DPS
- Three setting levels: Low (60±15 kPa), Medium (90±15 kPa), High (120±15 kPa)
- Alarms
- Syringe holder not Fixative, syringe plunger disengaged, Error in syringe flange insertion, syringe not calibrated, blockage, syringe empty, abnormal rate, empty battery, no battery, infusion complete, syringe near empty, no action, low battery level
- Three alarm volume levels: Low, Medium, or High
- Pulse Rate
- 5 ml: 0.1 ~ 200 ml/hour, 10 ml: 0.1-400 ml/hour, 20 ml: 0.1-800 ml/hour, 30 ml: 0.1-1200 ml/hour, 50 ml (60 ml): 0.1-2000 ml/hour
- Programmable and Adjustable
- Pulse Volume
- Range: 1.0 ~ 50.0 ml (Step 0.1 ml)
- Interface
- RS-232
- Power Source
- AC Power Supply: AC 100 to 240V (±10%), 50/60 Hz; DC Power Supply: 12~15V, Power >15W; Built-in Lithium Battery: Rechargeable, 7.2V, 2600 mAh. 8-10 hours of continuous operation.
- Accessories: AC power cord, Operating Manual
- Protection Class
- Class I, Type CF, IP34
- Dimensions / Net Weight
- 240 mm * 150 mm * 117 mm, 2.0 kg
- Packing Size / Gross Weight
- 300 mm * 260 mm * 160 mm, 3.0 kg