CROSS MOVING STAGE, HEATED, FOR ZEISS AXIOSCOPE.A1
Guaranteed safe payment
CROSS MOVING STAGE, HEATED, FOR ZEISS AXIOSCOPE.A1
This cross-moving heated stage is designed to seamlessly integrate with the ZEISS Axioscope A1 microscope, allowing precise and stable temperature control of samples during observation. It provides smooth bidirectional movement on orthogonal axes while maintaining a controlled thermal environment, making it ideal for live cell imaging or material analysis under heat influence.
Built-in heating capability to maintain the sample temperature slightly above ambient.
High thermal stability and heat capacity for continuous temperature adjustment.
Integrated safety feature limits maximum temperature to prevent overheating.
Compatible with a wide range of cultivation vessels or sample holders when used with appropriate guides and frames.
Temperature sensor: Pt100.
Heating limited by a thermal protection switch to a safe level (approximately 70 °C).
Operates at low voltage (e.g., 24 V), with moderate power consumption (up to ~2.2 A).
Observation opening sized to accommodate typical sample vessels (e.g., ~25 × 47 mm).
The stage allows cross movement of the sample while providing stable heating. Temperature increase is determined and controlled by an internal thermal protection switch.
Movement and heating are controlled via compatible control units; ensure appropriate object guides or mounting frames are installed to securely position the sample vessel.
Temperature settings or operating conditions should be determined by a qualified professional based on the sample type, experimental requirements, and device specifications.
Main Benefits
Precise movement on cross axes for accurate sample positioning under the microscope.Built-in heating capability to maintain the sample temperature slightly above ambient.
High thermal stability and heat capacity for continuous temperature adjustment.
Integrated safety feature limits maximum temperature to prevent overheating.
Compatible with a wide range of cultivation vessels or sample holders when used with appropriate guides and frames.
Construction
Aluminum structure with a black anodized coating.Temperature sensor: Pt100.
Heating limited by a thermal protection switch to a safe level (approximately 70 °C).
Operates at low voltage (e.g., 24 V), with moderate power consumption (up to ~2.2 A).
Observation opening sized to accommodate typical sample vessels (e.g., ~25 × 47 mm).
Instructions for Use
This stage is mounted in place of the standard stage on the ZEISS Axioscope A1 and requires connection to a compatible temperature control unit.The stage allows cross movement of the sample while providing stable heating. Temperature increase is determined and controlled by an internal thermal protection switch.
Movement and heating are controlled via compatible control units; ensure appropriate object guides or mounting frames are installed to securely position the sample vessel.
Temperature settings or operating conditions should be determined by a qualified professional based on the sample type, experimental requirements, and device specifications.